Pageloader

Reactor 500 L, 100 bar, 250°C

//Reactor 500 L, 100 bar, 250°C
Reaktor 500 L, 100 bar, 250°C
  • allowablepressure -1 to 100 bar(g)
  • maximum temperature250°C
  • volume530 L (internal diameter 700 mm)
  • wettedmaterial DIN WNr. 1.4404
  • heatingjacket (6 bar, 1.4301)
  • internalsurface grinded Ra<=0,8 μm
  • double mechanicalseal EagleBurgmann
  • 3-bladed stirrer
  • 7,5 kW drive withfrequency converter
  • air coolingof bearing
  • variablespeed 0 to 680 RPM
  • Ex proof
Investor

JSC Olainfarm, Riga-Olaine, Latvia